P05E2
A/C Refrigerant Pressure Sensor B Circuit Intermittent/Erratic
The refrigerant pressure sensor (three wires, 5 V reference, signal rising with pressure) tells the engine module the A/C pressure; it uses it to switch the radiator fan, to block the compressor at too high or too low pressure and to pre-control idle load. CARB requires such inputs to be checked for circuit faults and plausibility, but they need not light the lamp if they do not affect emissions. 'Intermittent/Erratic' means the signal jumps implausibly fast or briefly leaves its valid range without staying low or high long enough for those codes. Sensor B is a second pressure sensor; which one depends on the maker – typically the low-pressure side or a second circuit in heat pump systems. Its other codes are P2515–P2518. No manufacturer document available to us uses P05E2, so this follows the sensor A family. Expect the A/C or heat pump to switch off intermittently.
Possible causes
- Loose contact or corrosion at the sensor B connector high
- Chafed or broken harness medium
- Sensor B faulty medium
- 5 V reference or control module low
Symptoms
- A/C or heat pump intermittently switched off
- Heating or cooling output fluctuates
- Warning lamp depending on the maker
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P05E2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.