P05BD
Stop-Start Mode Switch Circuit Range/Performance
The stop-start off switch lets the driver disable automatic engine stop for the current drive. It is read directly or via another module over CAN – on Stellantis' 2025 Ram 1500 it sits in the electronic shifter module. CARB names a stop-start diagnosis as its example of an emission-neutral diagnosis, so no warning lamp is required; stop-start is usually just disabled. P05BD means the switch signal is valid but implausible. On the 2025 Ram 1500 Stellantis sets it when the engine module receives 120 presses of the stop-start button within 2 minutes over CAN – a sticking or bouncing button or a flood of messages. The first fix is an engine module software update, not parts; Stellantis warns not to replace the ignition switch for it.
Possible causes
- Engine module software (Stellantis: fixed by update) high
- Sticking or bouncing stop-start button in the shifter module medium
- Very frequent pressing by occupants low
- Shifter module faulty low
Symptoms
- Usually no noticeable symptoms
- Stop-start button not reacting or status jumping
- Code stored in the engine module
Inspection / repair
- Difficulty: easy
- DIY: shop recommended
What Pro shows you for P05BD
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.