P058A
Battery Monitor Module Performance
The battery monitor module (intelligent battery sensor) sits on the negative terminal of the 12 V battery: a shunt measures current, electronics also measure voltage and temperature and calculate state of charge, health and cranking ability, reporting over LIN. Energy management uses the data for alternator control, idle boost and stop-start release, which is why the engine module diagnoses it. GM sets P058A–P058F in its engine modules from 2016 as type B, warning lamp after two trips. P058A means the module reports an internal fault of its own over LIN. GM checks it every 250 ms above 9 V, without LIN faults and at outside temperatures of −20 to 50 °C. Battery data are then unreliable – stop-start is blocked and the alternator usually runs a fixed substitute voltage. Loss of communication is a separate U code.
Possible causes
- Battery sensor faulty internally high
- Poor supply or ground at the sensor (loose terminal, corroded connector) medium
- Sensor not relearned after battery replacement or disconnection medium
- Module or engine module software low
Symptoms
- Check engine light on
- Stop-start not available
- No driveability problems