P056D
Reductant Control Module System Voltage
Diesels with SCR may have a separate module for AdBlue/DEF dosing (pump, heaters, dosing valve) talking to the engine module over CAN. It measures its supply; outside its window no safe dosing is possible, so dosing and SCR diagnoses are suspended and NOx rises, and if it persists the SCR warnings and power limits apply. No manufacturer document available to us uses P056D – Ford's diesel reports the dosing module supply as P21CB below 8.5 V and P21CC above 19 V. CARB requires SCR modules to be monitored.
Possible causes
- Fuse, relay or supply line of the DEF module high
- Corrosion at module connector or ground (underbody, road salt) medium
- System under- or overvoltage medium
- Module faulty low
Symptoms
- Check engine light and DEF warning
- Possible countdown to start inhibit or power limit
- Further SCR codes
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P056D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.