P0537
A/C Evaporator Temperature Sensor Circuit Low
The evaporator temperature sensor, an NTC thermistor behind the evaporator, prevents icing: near 0–3 °C the compressor is switched off or reduced. Usually the climate module reads it and reports body codes; P0535–P0539 only arise where the engine module controls the compressor and reads the sensor. P0537 means the signal voltage is below its limit; with the usual NTC voltage divider that is a signal shorted to ground or a shorted sensor, read as implausibly warm – icing protection may then fail. No manufacturer document available to us uses this code; the description follows CARB's input component rules.
Possible causes
- Signal line shorted to ground high
- Sensor shorted internally high
- Condensate in the connector (leakage to ground) medium
- Engine module low
Symptoms
- Air conditioning not cooling
- Possible icing
- Compressor permanently on or locked out
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0537
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.