P0527
Fan Speed Sensor Circuit Range/Performance
Engine-driven fans with an electronically controlled viscous clutch (GM petrol SUVs and pick-ups 2004–2006, GM Duramax, Ford 6.7 L Power Stroke) have a Hall sensor reporting fan speed; the fan checks P0483, P0494 and P0495 need it. P0527 means a signal is present but implausible – spikes, jumps or a speed that does not fit the clutch command and engine speed. No manufacturer document available to us uses P0527; GM covers implausibility through P0483 (target versus actual) and P0493. CARB requires input components used by other diagnoses to be checked for plausibility.
Possible causes
- Sensor or trigger element damaged, wrong air gap medium
- Interference or ground fault on the sensor line medium
- Viscous clutch slipping or sticking (real speed off) medium
Symptoms
- Check engine light (depending on the maker)
- Unsteady fan control
- Fan permanently on
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0527
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.