Powertrain
generic / SAE
P04BC
Fuel Fill Door Lock Control Range or Performance
Fuel Fill Door Lock Control Range or Performance: the component is electrically intact but its response does not match the command.
SystemPowertrain
Typegeneric / SAE
GroupP0
Range / number4 / BC
Possible causes
- Actuator slow or worn high
- Linkage binding due to dirt or ice medium
Inspection / repair
- Difficulty: easy
- DIY: possible
- Estimated cost: 80–280 €
- Estimated time: 0.5–1.4 h
- Component: fuel fill door lock actuator
- Component: fuel fill door lock position sensor
Sources
References
sae:J2012