P042F
EGR A Control Stuck Closed
Exhaust gas recirculation (EGR) routes part of the exhaust back into the intake to lower combustion temperature and NOx. P042F means EGR valve A does not follow the opening command: its actual position stays more closed than commanded although the actuator works with high opening duty. GM's diesels of 2016/17 set it after about 1–8 s with MIL on the first trip; a GM bulletin covers it on the 2017 Cruze diesel. Ford petrol engines use position limits for 4 s; Ford diesels report both directions under P042E. With too little EGR, NOx rises, petrol engines may knock and P0401 can follow.
Possible causes
- Valve coked or seized in the closed position high
- Actuator motor or gear weak or faulty medium
- Position sensor or connector gives a wrong value medium
- Icing in winter (temporary) low
Symptoms
- Check engine light on (GM after one trip)
- Usually no driveability problems
- Possibly pinging (petrol) or higher NOx
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P042F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.