AIR System Switching Valve A Circuit Shorted
The switching valve is the electrically driven valve of this path – a solenoid valve, or on Pierburg/VW systems an electric changeover valve that applies vacuum to the pneumatic combination valve; valve A serves the first path or bank 1, valve B the second. P0414 means the control circuit of valve A is shorted. A short to ground keeps the valve energized and open; a short to supply or a shorted coil overloads the driver, which many modules then switch off for the rest of the trip. An open valve with the pump running can also set P2440, and exhaust can reach the pump if the check valve leaks. Subaru names P0414 in its bulletin for the two-valve system.
Possible causes
- Valve coil with shorted turns (water ingress) high
- Wire chafed against ground or supply medium
- Moisture or corrosion in the connector medium
- Driver in the engine module low
Symptoms
- Check engine light on
- Secondary air inactive
- Secondary air readiness not set (emission test)
- Driving normal
Inspection / repair