P0413
AIR System Switching Valve A Circuit Open
The switching valve is the electrically driven valve of this path – a solenoid valve, or on Pierburg/VW systems an electric changeover valve that applies vacuum to the pneumatic combination valve; valve A serves the first path or bank 1, valve B the second. P0413 means the control circuit of valve A is open: with the driver switched off the module does not see the expected supply or pull-up level. The check runs continuously. Subaru's two-valve system assigns valve A to bank 1, and its bulletin advises checking the valve of the other bank as well. The valve stays shut and the bank gets no secondary air; flow codes such as P0411 may follow.
Possible causes
- Wire to the valve open or connector loose or corroded high
- Valve coil burnt out high
- Fuse of the valve supply blown medium
- Engine module low
Symptoms
- Check engine light on
- Secondary air inactive
- Secondary air readiness not set (emission test)
- Driving normal
Inspection / repair
- Difficulty: easy
- DIY: possible