Powertrain
generic / SAE
P02E0
Diesel Intake Air Flow A Control Circuit/Open
The drive circuit for the diesel intake air-flow control valve A is open. This valve (also called intake throttle, swirl flap actuator, or anti-shudder valve) closes the diesel intake to control airflow during regeneration and shutdown.
SystemPowertrain
Typegeneric / SAE
GroupP0
Range / number2 / E0
Possible causes
- Actuator winding open high
- Open wire to actuator medium
- Pin pushed back out of connector body low
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 120–900 €
- Estimated time: 0.7–3 h
- Component: diesel intake throttle
- Component: diesel intake throttle actuator
- MIL / check engine light
- emissions-relevant
Sources
References
sae:J2012