O2 Sensor Delayed Response - Lean to Rich Bank 1 Sensor 1
The upstream oxygen sensor (sensor 1, before the catalytic converter) is the main control sensor for the air-fuel mixture. 'Delayed response' means the sensor starts reacting too late, or does not reach the target level at all, after the mixture has changed. This code covers the lean-to-rich direction, tested when fuel returns or the control module briefly enriches the mixture. GM measures the upstream switching sensor's delay while the mixture is enriched for the downstream tests and fails a filtered delay above about 0.58 s (fallback 1.9 s) after one trip; the test needs the rich-to-lean counterpart P015A completed first. CARB requires separate detection of slow and delayed faults in each direction (phased in from 2009 for downstream and 2011 for upstream sensors).
Possible causes
- Upstream oxygen sensor aged or poisoned (silicone, oil, coolant, soot) high
- Exhaust leak ahead of the sensor (manifold, flange) medium
- Mixture fault: intake air leak, injectors, fuel pressure, air flow sensor low
- Sensor heater weak, sensor too cold low
- Connector, wiring or control module software low
Symptoms
- Check engine light on
- Slightly higher consumption or rough idle possible
- Higher emissions, possible emissions test failure
- Often no noticeable symptoms
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for P015B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.