P0150
O2 Sensor Circuit Bank 2 Sensor 1
The oxygen sensor before the catalytic converter on bank 2 (sensor 1) is the main control sensor for the mixture. It is either a switching sensor (about 0.1 V lean to 0.9 V rich) or a wide-band sensor that works with a pump current evaluated by an interface chip. Bank 2 exists only on engines with two exhaust manifolds. P0150 is the bank 2 counterpart of P0130. Ford used it up to 2010 as the collective code for wiring faults of the bank 2 wide-band sensor reported by the interface chip and has used specific codes since 2011 (P0151, P0152, P2240/P2247/P2254). Other makers fill it as for bank 1 – an interface voltage check, a collective code or a plausibility test. No bank 2-specific manufacturer thresholds were found. If P0130 and P0150 appear together, look for a shared cause such as supply, ground or the control module. A stored code usually switches mixture control to open loop and suspends adaptation and converter monitoring.
Possible causes
- Wiring or connector of the bank 2 upstream sensor damaged, corroded or wet high
- Oxygen sensor faulty internally high
- Exhaust leak ahead of the sensor or mixture fault (plausibility versions) medium
- Control module or sensor interface chip faulty low
Symptoms
- Check engine light on
- Higher consumption, possibly rough running (no mixture control)
- Higher emissions, possible emissions test failure
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0150
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.