P006A
MAP - Mass or Volume Air Flow Correlation Bank 1
The engine control module compares the air quantity measured by the mass air flow sensor with the quantity it calculates from manifold pressure, engine speed and temperature. P006A is set when the two deviate too far. A typical cause is an exhaust gas recirculation valve that does not close: recirculated exhaust raises manifold pressure without passing the air flow sensor. Air leaks, a leaking crankcase ventilation hose or a dirty sensor have the same effect. Each sensor can be electrically fine on its own; regulations require such plausibility checks for input sensors with a code of their own.
Possible causes
- EGR valve dirty or sticking open high
- Air leak or crankcase ventilation hose leaking medium
- Mass air flow sensor dirty or manifold pressure sensor faulty medium
- Air filter or intake restricted low
Symptoms
- Check engine light on
- Rough running
- Slight hesitation when accelerating
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P006A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.