P0050
HO2S Heater Control Circuit (Bank 2 Sensor 1)
The heated oxygen sensor on bank 2 is the upstream sensor (sensor 1, before the catalytic converter), used for mixture control. Its heating element brings it quickly to operating temperature. Typically the heater receives battery voltage via a fuse, and the engine control module switches the ground side with a pulsed signal while checking that the circuit state matches the command. P0050 is the general circuit fault: the measured state of the heater circuit does not fit the command, most often because the circuit is interrupted. Which physical fault sets the general, low or high code is defined by each manufacturer. Without heating, closed-loop mixture control starts late and cold-start emissions rise. Bank 2 codes occur only on engines with two exhaust banks (V or boxer engines).
Possible causes
- Heating element inside the sensor burnt out high
- Wire or connector damaged by heat or road spray high
- Heater fuse blown; a shared fuse can set several heater codes medium
- Output driver or software of the engine control module low
Symptoms
- Check engine light on
- Usually no noticeable drivability problem
- Closed-loop control starts late after a cold start
- Emissions test or readiness check failed
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0050
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- law.cornell.edu/regulations/california/13-CCR-1968.2
- saabwisonline.com/9-4x/2011/2-engine/engine-management-and-fuel-system-v6/fault-diagnosis-diagnostic-trouble-codes/dtc-p0030-p0036-p0050-p0053-p0054-p0056-p0059-p0060-p0135-p0141-p0155-or-p0161-lf1-lfw
- gsi.ext.gm.com/gmspo/mode6/pdf/2007/07_GRP16_PHT_ECM.pdf
- WikipediaOxygen sensor