C061F
Variable Effort Steering Actuator Control Circuit Performance
C061F covers an actuator circuit that is electrically intact but does not behave as commanded: the current does not follow the request, or the expected change in effort fails to show up. In Magnasteer the coil runs from about −3 A to +3 A, and the current reverses around mid speed, so tracking errors appear as wrong feel in town or on the highway. The Steering Solutions patent stresses that the magnetic null must line up with the valve's centre for the gear to work properly; a later variant without permanent magnets only raises effort with speed. Coil heating, a sticky valve or a damaged magnet ring fit this code. GM's scan tool can run a function test that sweeps the current. No maker publishes C061F.
Possible causes
- Magnetic null shifted from valve centre, damaged magnet ring medium
- Sticking rotary valve from contaminated fluid medium
- High resistance in connector or wiring limiting coil current medium
- Wrong or missing vehicle speed input to the controlling module low
Symptoms
- Steering effort wrong for the speed or changing unexpectedly
- Pull to one side with no alignment fault
- Steering warning on some vehicles
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for C061F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.