C05F5
4WD/AWD Range Actuator Control Circuit/Open
The range actuator is the electric gear motor that moves the transfer case between high range, neutral and low range. With this code the controller finds no usable current path in the motor drive circuit, usually an open winding, wire or connector. Automotive H-bridge drivers such as the TI DRV8873-Q1 run a dedicated open-load test besides short and overcurrent checks. Stellantis uses its own code C140A-13 for an open shift motor drive in bulletin 08-237-23 for 2023 Ram 1500 trucks, caused by an unseated shift motor connector; Ford asks in SSM 48300 for Super Duty trucks to check loose pins, contamination and broken wires before replacing a shift motor. No maker documents C05F5 itself. With the circuit open, range shifts are impossible.
Possible causes
- Shift motor connector not fully seated or corroded high
- Broken wire between control module and motor medium
- Open motor winding or worn brushes in the range actuator medium
- Failed output stage in the control module low
Symptoms
- 4WD service message, low range cannot be selected
- Range indicator flashes or does not change
- Transfer case stays in its last position
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for C05F5
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.