C05BE
Brake Booster Motor B Position Sensor Supply Circuit High
C05BE is stored when the 5 V feed of motor B's position sensor exceeds its upper limit. No manufacturer documents it publicly. Two mechanisms are typical: the supply line has contacted a wire carrying battery voltage, or the reference ground of the sensor side has lifted, which makes every voltage measured against it look too high. Denso's patent illustrates the ground effect for a sensor read through a pull-down: a broken ground drives the signal above 4.7 V. In Hitachi Astemo's cross-check a rising ground pulls both references down while the monitor values stay put, which separates a ground fault from a true overvoltage. TI's tracker cuts its output path when shorted to battery. The booster then drops channel B and runs with motor A or reduced assist.
Possible causes
- Motor B sensor supply shorted to a battery-voltage wire high
- Open or high-resistance sensor ground raising the measured voltage medium
- Second sensor supply regulator out of regulation low
Symptoms
- Brake warning lamp and assist warning
- Possibly further sensor codes if a shared ground is affected
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for C05BE
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.