C05BC
Brake Booster Motor B Position Sensor Supply Circuit/Open
C05BC reports an interrupted supply for the position sensor of booster motor B. A B channel exists where the actuator carries a second motor or winding set, or measures its rotor angle twice for redundancy. No manufacturer documents C05BC publicly. Hyundai Mobis describes a brake actuator with a dual-winding motor whose two power modules are fed separately; when one is diagnosed faulty it is shut down and the full current command passes to the other. Hitachi Astemo pairs each sensor supply with its own angle and torque sensor and keeps the motor running on the healthy set. As in Denso's analysis, a broken feed drags the signal to 0 V. The usual result is a brake warning with reduced assist, while full failure of boosting is avoided.
Possible causes
- Broken wire or pushed-back pin in the motor B sensor supply high
- Second sensor supply output in the control unit failed medium
- Open inside the motor B position sensor low
Symptoms
- Brake warning lamp, assist may remain partly available
- Reduced maximum assist or slower pressure build-up
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for C05BC
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.