C05A6
ABS Pump Motor Supply Voltage B Circuit High
C05A6 says the second pump motor feed, supply B, carries more voltage than allowed. Overvoltage strains the motor and above all the transistors that switch it; gate driver ICs for brake motors such as TI's DRV8305-Q1 therefore watch their supply and raise an overvoltage warning in the mid-30 V range. Typical causes are a faulty alternator or DC/DC converter regulator, jump-starting or charging at too high a voltage, or a measuring fault in the module. No maker documents C05A6 publicly. As an orientation, Mitsubishi's 2023 Outlander PHEV specifies 10–16 V for the motor feed and stores C1056-17 once the brake unit's supply reaches 16 V within 1 s. Where the motor has two power modules on separate inputs, as in a Hyundai Mobis patent, the faulty side can be disabled while the other keeps working.
Possible causes
- Alternator or DC/DC converter regulating too high high
- Jump start or battery charger with excessive voltage medium
- Voltage measurement fault in the brake module low
Symptoms
- ABS/ESC warning lamp on, possibly with other overvoltage codes
- Very bright lights or battery warning if charging is the cause
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for C05A6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?