C0586
Brake Booster Motor B Phase U-V-W Circuit Range/Performance
C0586 is set when the B drive stage of the booster motor is electrically connected but behaves implausibly: phase currents that do not match the command, a transistor pair conducting at once, or a bridge driver that fails its start-up self-test. Nobody publishes limits for side B. GM's tests for motor A under C0582 – more than 150 A in a cross-switching test, an idle phase not at 1.65 V – show what such a check looks like. TI's DRV3245Q-Q1, designed for electric brake and brake assist, adds shoot-through prevention and gate-source monitoring for the same purpose. In a dual-winding motor like the Hyundai Mobis one, diagnostics classify each power module as healthy or failed; the failed one is switched off, so the driver may notice a weaker or slower pedal response.
Possible causes
- Bridge driver of channel B failing its self-test medium
- Current measurement of channel B drifting, currents no longer match the command medium
- Control unit software issue, resolved by update where available low
Symptoms
- Brake warning or service message
- Pedal response weaker or slower than usual
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for C0586
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.