C0536
Motor Control B Circuit/Open
Motor control B finds its load missing. The module expects a closed path through the windings of channel B and sees an open circuit instead – a pulled connector, a cut lead, corroded pins or an internal break in the motor. Brake controllers have run dedicated open-circuit routines for pump motors for decades, as in a Kelsey-Hayes patent (now ZF) that checks the motor circuit while the pump is not requested; current bridge driver chips like the DRV8873-Q1 from TI provide open-load detection both in standby and during operation. J2012 does not identify the motor behind B and no public manufacturer documentation of C0536 was found. Until repaired the motor stays dead and the function it serves is unavailable; compare C0531 for channel A.
Possible causes
- Connector to motor B pulled off or pins corroded high
- Motor lead cut or broken in the harness medium
- Internal break in motor B (winding, brush) medium
Symptoms
- Warning lamp of the affected system on
- Motor B shows no reaction
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for C0536
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?