C0535
Motor Control B Range/Performance
Second motor channel B fails its plausibility check: wiring and supply test fine, yet the motor's reaction to commands is wrong, for example too little speed, a delayed start or no stop. Where a controller drives two motors or two channels, A and B separate them; J2012 does not say which motor B is, and no manufacturer publicly assigns C0535, so the meaning must come from the vehicle's own service data. How such a check can work is shown by an AlliedSignal patent now held by Bosch: after shut-off a spinning DC motor acts as a generator, and a voltage collapse faster than roughly 134 V/s means it never really turned. Causes lie mostly in the motor or the driven mechanism; the channel A counterpart is C0530.
Possible causes
- Driven mechanism of motor B binding or blocked high
- Motor B worn and too slow medium
- Faulty speed or position feedback in the control unit low
Symptoms
- Warning lamp of the affected system on
- Function of motor B slow, incomplete or unavailable
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for C0535
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.