C0532
Motor Control A Circuit High
Motor control A reads high: a motor output sits near supply voltage although the driver commands it low or off. That points to a short to battery voltage in the motor leads or a high-side switch that no longer opens. J2012 leaves the motor unnamed and no manufacturer publication assigning C0532 was found. Bosch's US5329238 compares each terminal with limits scaled to the measured supply and treats an exceeded upper limit as a short to plus, after which drive is cut in one or both directions; TI's DRV8873-Q1 guards against shorts to battery with overcurrent protection that disables the affected half-bridge. If the motor stays energised it may run on or overheat; otherwise the function simply drops out with its warning lamp.
Possible causes
- Motor lead chafed against a live wire high
- High-side switch in the control unit stuck on medium
- Moisture bridging pins in the connector low
Symptoms
- Warning lamp of the affected system on
- Motor A runs on or gets hot
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for C0532
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.