Front Blower Motor Circuit Low

The HVAC control module has detected low voltage or a short to ground in the front blower motor circuit. The blower may run too slow or not at all.

SystemBody
Typegeneric / SAE
GroupB0
Range / number1 / 81

Possible causes

  • Blower motor worn or seized high
  • Blower resistor or power module failed medium
  • Wiring shorted to ground low

Symptoms

  • Warning light or symbol related to the affected system
  • Comfort or safety function impaired

Inspection / repair

  • Difficulty: medium
  • DIY: possible
  • Estimated cost: 80–500 €
  • Estimated time: 0.5–2.5 h
  • Component: front blower motor
  • Component: blower resistor or module
  • Component: hvac control module

Sources