B011D
Fluid Reservoir Level Sensor B
B011D concerns level sensor B. Not every washer tank relies on a float. Volkswagen's bulletin 2037322 (2015) describes its washer level sensor G33 as a part whose reading depends on the fluid itself: the wrong mix or additives coat the sensor, cut its sensitivity and leave the lamp lit with a full tank; the remedy is draining, cleaning the sensor and refilling with approved fluid. Sensors moulded into the reservoir cannot be replaced on their own. A non-contact alternative is the capacitive single-point detector of patent US5017909A, fixed on the outside wall at the minimum level, where the liquid shifts the measured capacitance. Which principle sits behind letter B is not published, and no maker lists B011D publicly.
Possible causes
- Deposits from unsuitable washer fluid or additives on the sensing surface high
- Sensor electronics or electrodes defective medium
- Open or short in the sensor wiring low
Symptoms
- Warning lamp lit with a full reservoir, often after a change of washer fluid
- Level warning appears late or not at all
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for B011D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.