B011A
Camera Washer Actuator R
B011A covers actuator R. Some camera cleaners use air as well as fluid, so the actuator may be a blower as much as a pump. Thunder Power's patent US9539988B2 places a water nozzle and an air nozzle at a reversing camera: air blasts first, then unheated fluid, and below about 0 °C heated fluid, while an infrared drop sensor behind the lens decides when cleaning is needed. Denso's US9180840B2 opens its fluid valve only after the air has started and keeps it open for 0.1 to 0.5 s; in its tests at least about 70 % of salty mud had to come off for a usable picture. Air blowers for sensors have their own codes from B0100. Which camera R serves is not published; no manufacturer documents B011A.
Possible causes
- Pump, valve or air blower R electrically open or shorted high
- Heater element in the camera wash circuit defective, affecting cold-weather operation medium
- Corroded plug at actuator R low
Symptoms
- Camera served by actuator R is neither blown nor sprayed clean
- Drops or mud remain on the lens; assistance functions may warn of a blocked camera
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for B011A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.