B0104
Sensor Cleaning Air Blower Actuator A Control Relay
B0104 points at the relay that switches power to blower A. A fan motor draws more current than a module output can carry, so a relay is a natural choice: the module energises the coil (terminals 85/86 in HELLA's scheme) and the contact (30/87) feeds the motor. HELLA's relay brochure explains that coils may carry a diode or resistor against switch-off spikes and that relays are checked for coil resistance and contact voltage drop. Faults here are an open or shorted coil, welded or burnt contacts, or a missing feed. Ford's US12115948B2 places the blower on the sensor bracket, and the Ford tiara uses that air to shield lenses from insects, as eeNews reports. No carmaker publishes B0104; the B-side relay is B0105.
Possible causes
- Burnt or welded contacts in the blower A relay high
- Relay coil open or its control wire interrupted medium
- Blown fuse or loose socket on the relay supply side medium
Symptoms
- Blower A dead, or running without command if contacts are welded
- No relay click when cleaning is requested
- Sensor cleaning warning with possible loss of assistance functions
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for B0104
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?