Body
generic / SAE
B0006
Driver Frontal Deployment Loop Short to Ground
One of the deployment leads for the driver frontal airbag is shorted to ground. The SRS module disables deployment of the affected stage to prevent unintended firing.
SystemBody
Typegeneric / SAE
GroupB0
Range / number– / 06
Possible causes
- Chafed wiring contacting metal high
- Water intrusion at connector medium
- Internal airbag module short to housing low
Symptoms
- Warning light or symbol related to the affected system
- Comfort or safety function impaired
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
- Estimated cost: 150–1000 €
- Estimated time: 1–3 h
- Component: driver airbag module
- Component: srs wiring
- Component: clock spring
Sources
References
sae:J2012